<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-04 23-18-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 41 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 1.9 kHz 68 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 61 kHz 12111 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,1 dBr 2,83 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 23:18, 4.03.2026
RT
"ROS & BRUNO MARS - APT. "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 61 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2026/03/04 23.17.01 Total samples: 12111 Equivalent time: 0:10:05 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,2 dBr MIN: 0,1 dBr AVE: 2,83 dBr % above 12,2 dBr: 0,0 Last value: 4,5 dBr (2026/03/04 23.17.01) 23.04 23.06 23.08 23.10 23.12 23.14 23.16 0 2 4 6 Pm [dBr]